DVLS Sour Gas Analyzer


Gas streams from process plants may vary greatly in compositional concentration ranges. Consequently, different sample streams could require adjusted sample introduction procedures for the GC analysis, such as purge time, sub ambient sampling pressure or inert gas flushing. Due to these variations the gas sampling and analysis may be challenging for the operator. Da Vinci Laboratory Solutions (DVLS) offers a turnkey gas chromatographic (GC) solution for the automated sampling, flushing and GC analysis of complex gas streams.

Automated analysis of complex gas samples


Correct sampling of gas streams is critical for a representative analysis of a gas composition and the accurate calculation of its heating values such as British Thermal Unit (BTU). To provide a user-friendly solution Da Vinci introduces the DVLS Gas Sampling Station. This station is a software controlled device that automates the sampling, purging and interfacing with the Chromatography Data System (CDS) software.

The design of the station includes four separate sample inlets to prevent any cross contamination and a controlled vacuum pump for sub-ambient sampling from 100 to 1000 mBar. The station is also corrosion resistant for samples containing high concentrations of Hydrogen Sulfide.
The Gas Sampling Station is controlled by the Time Scheduler software. This tool is used to program the pre-analysis sampling sequencing and corresponding GC analysis in the CDS.

 

 

  • Applications

    The DVLS Sour Gas Analyzer determines the composition of four different gas streams:

    • Export Gas having a low Hydrogen Sulfide content (<1000 ppm) at a low pressure [< 1 Bar];
    • Sweet Gas having a low Hydrogen Sulfide content (1-200 ppm) at a high pressure [1 - 100 Bar];
    • Acid Gas having a high Hydrogen Sulfide content (25 – 90%) at a low pressure [< 1 Bar];
    • Sour gas having a high Hydrogen Sulfide content (1-10%) at a high pressure [1 - 100 Bar].
     
    The DVLS Sour Gas Analyzer is equipped with three channels for the compositional analysis of the gas streams:
    1. The FID Channel determines C1-C8+ hydrocarbons and BTEX;
    2. The PFPD Channel analyzes H2S, COS, Mercaptans, Sulfides in the range from 1 to 1000 ppm;

    3. The TCD Channel determines Nitrogen, CO2, H2S and COS in the range of 0,01 to 100%. 

     

    • Configuration

      The DVLS Sour Gas analyzer uses an Agilent GC with electronic pneumatics control (EPC) configured with three different channels. Each channel includes the required columns, valves, inlets and a detector: TCD, FID or PFPD.
      The analyzer is also equipped with a side carrier that contains the columns and valves, which enables a built-in column conditioning. The gas samples are simultaneously injected into the three separate channels.

      The Agilent GC is controlled by Agilent OpenLab CDS software for instrument configuration, method setup, instrument control and data acquisition. The DVLS PetroReporter automatically calculates gas properties such as Molar Weight, Gas Density, CV and BTU. The TimeS controls the various modules, from pre-analysis sampling sequencing to sample purging, GC analysis up to reporting of the gas properties by a simple push of the button.

배송 및 주요 안내

출고시스템

1.오후 3시까지의 주문 결제건 당일 출고 (단 재고 보유 상품일 경우에 해당)

2. 애질런트 미재고 상품의 경우 (해외수입의경우) 2주~4주이내 출고 (토.일, 공휴일제외 배송사 사정에 따라 다름)

3. 그외 장비의 경우 제조사별 별도 납기 확인 필요. ( 대부분 3~4개월이내 출고)

4. Bel-Art 재품은 재고표기없는 제품도 별도 창고운영으로 재고보유분은 당일 또는 익일 출고가능

배송안내

1.배송방법: 택배

2.배송가능지역: 전국

3.배송비: 

  1)일반고객,소비자 

     - 주문금액 50,000원 이상 : 판매자 부담 (단, 택배배송 불가능 상품은 고객 부담)

     - 주문금액 50,000원 미만 : 고객부담 (착불 또는 주문시 결제 가능)

  2) 납품업체, 협력업체

     - 주문금액 200,000원 이상 : 판매자 부담 (단, 택배배송불가 상품은 고객 부담. 제주도 및 도서 산간지역은 추가 운임비가 발생됨)

     - 주문금액 200,000원 미만 : 고객부담 (착불 또는 주문시 결제 가능)

  3) 공통

      - 재고 보유 상품과 미 보유 상품을 동시에 주문 하시는 경우, 재고 보유 상품의 금액(출고금액) 기준으로 운임비가 부과됩니다.

4.배송기일: 재고 상품의 경우 주문 또는 결제일 다음날로부터 약 2~4일 이내, 미재고 상품의 경우 2주~4주이내 발송  (토 / 일 / 공휴일 제외, 배송사 사정에 따라 다름)

5.주의사항: 상품특성 (설치상품, 상품크기 등) 또는 지역여건 (산간, 도서지역)에 따라 배송이 지연되거나 추가 배송비가 발생할 수 있습니다.

             배송기일은 참고용으로 재고상황 및 상품특성, 배송여건에 따라 실제 발송일과 차이가 있을 수 있습니다.

 

반품/교환안내 

 1. 교환 및 반품이 가능한 경우

    1) 상품배송 완료 후 7일 이내에 상품에 하자가 없는 경우.

    2) 포장상태에 이상이 없고, 재판매가 가능한 경우 (단, 왕복 택배비 7,700원을 부담하셔야 합니다)

  2. 교환 및 반품이 불가능한 경우

    1) 반품 요청 기간 7일이 지난 경우

    2) 주문 당시 재고가 없어 해외 발주(수입) 상품의 경우

    3) 포장을 개봉하였건 포장 및 제품이 훼손되어 상품가치가 현저히 상실되고 재판매가 불가능한 경우

    4) 구매자의 책임 있는 사유로 상품 등이 멸실 또는 훼손된 경우

    5) 고객의 주문에 의해 제작되는 주문제작 상품의 경우

    6) 반품으로 배송되는 과정 중 파손된 경우 (택배사의 부주의 혹은 부실포장으로 인한 파손이므로 반품 불가)

    7) 드라이아이스 포장상품의 경우

    8) 유효기간이 있는 제품

 3.교환/반품문의

   1) 02-898-3352 또는 bsc_info@biospechrom.com


결제안내

1. 결제지원수단 : 무통장입금 (실시간 계좌이체, 신용카드는 추후 운영 예정),연구비카드,psys url결재

2. 주의사항 : 주문 및 결제 확인 과정에서 도난카드, 타인명의의 주문, 비정상적인 대량 주문이 확인되는 경우는 임의로 주문 및 결제를 제한 할수 있습니다.